Skip to product information
1 of 4

SciMed

BOD Incubator 171L — 5°C to 50°C ±0.5°C, Dual Door, EPA Wastewater Testing Ready

BOD Incubator 171L — 5°C to 50°C ±0.5°C, Dual Door, EPA Wastewater Testing Ready

Regular price $14,999.00 USD
Regular price Sale price $14,999.00 USD
Sale Sold out
Doctor Recommended
No Rx Required
Ships Same-Day
30-Day Returns
Taxes included. Shipping calculated at checkout.

171-liter (6.1 cu.ft.) Biochemical Oxygen Demand incubator engineered to the 20°C ±1°C stability target required by EPA Method 5210B, Standard Methods for the Examination of Water & Wastewater 5210, and ASTM D888. 5-50°C operating range with Deluxe Digital PID Controller holding ±0.5°C accuracy. Dual-door design with transparent acrylic inner door for observation without cold-loss. LED interior with door switch. For municipal wastewater plants, environmental testing labs, pharmaceutical stability chambers, microbiology, and academic environmental engineering programs. $14,999 direct — versus $22,000-$35,000 for Thermo Scientific / VWR / Sheldon Manufacturing (SHEL LAB) equivalents.

✓ EPA Method 5210B Ready✓ 5-50°C Range✓ ±0.5°C Stability✓ 171L / 6.1 cu.ft.✓ Dual Door✓ PID Controller✓ 110V or 220V✓ Sealed Refrigeration
Where this sits in the market: Thermo Scientific Precision 815 BOD incubator (170L): $22,000-$28,000. VWR 2005 series BOD incubator (170L): $18,000-$25,000. Sheldon Manufacturing (SHEL LAB) SRI20 (170L): $16,000-$22,000. Percival I-30BLL: $28,000-$35,000. This SciMed 171L BOD incubator delivers the same 5-50°C range, same ±0.5°C stability, same PID digital controller, dual door, and sealed refrigeration at 40-50% of premium lab-instrument pricing — with same-day US ship vs 6-12 week manufacturer lead time. Same EPA Method 5210B qualification.

What a BOD incubator does

Biochemical Oxygen Demand (BOD) is the fundamental measurement of organic pollution in water. EPA Method 5210B requires wastewater samples to be incubated at 20°C ±1°C for 5 days while measuring dissolved oxygen depletion — the more DO consumed by microorganisms, the higher the BOD, the higher the organic pollution load. This measurement drives NPDES permit compliance for every municipal wastewater treatment plant and industrial discharger in the United States. The BOD incubator is the temperature-controlled environment where those 5-day incubations happen, typically running dozens of 300 mL BOD bottles simultaneously at rigidly held 20°C.

Beyond BOD, the same 5-50°C range enables microbiology (30°C, 37°C), plant tissue culture (25°C), seed germination testing, entomology rearing, pharmaceutical stability (25°C ± 2°C / 60% RH constant), and any application requiring tight temperature control across a moderate range.

Specifications

Chamber capacity 171 liters / 6.1 cu.ft.
Internal dimensions 505 × 415 × 830 mm (W × D × H)
Temperature range 5°C to 50°C
Stability ±0.5°C (typical, at 20°C setpoint after equilibration)
Uniformity ±1.0°C across chamber at 20°C
Controller Deluxe Digital PID controller with LED display
Ambient operating 15-32°C recommended
Chamber material Anodized aluminum or highly polished SS 304 (specify at order)
Exterior Thick mild steel, powder-coated matte finish
Outer door Double-wall with magnetic gasket + lock & key
Inner door Transparent acrylic — observe samples without cold-loss
Shelves 2 or 3 adjustable perforated stainless steel shelves (specify)
Interior lighting LED, door-switch activated (auto on/off)
Refrigeration Sealed system, high-efficiency compressor, environmentally-friendly refrigerant
Heating Integrated element for setpoints above ambient
Air circulation Advanced forced-air system for uniform distribution
Safety Compressor protection, over-temperature cut-out, low-refrigerant alarm
Power 110V or 220V AC, 50/60 Hz single-phase (specify at order)
Warranty 2-year parts + labor · 5-year compressor

EPA Method 5210B compliance

Method 5210B (5-day BOD test) requires the incubation environment to be 20°C ± 1°C for 5 days without variation greater than 1°C in any direction. Our ±0.5°C stability at 20°C setpoint provides a 2× safety margin against the ±1°C compliance requirement — critical for NPDES permit-compliant lab data.

Method 5210B, Standard Methods 5210, ASTM D888, and 40 CFR 136 discharge monitoring requirements are all satisfied by any BOD incubator holding 20°C ± 1°C. Our controller documentation + independent verification records (from your calibration provider) provide the audit trail wastewater plants need for state / EPA discharge monitoring reports.

Municipal wastewater plants: BOD is one of the two most-monitored NPDES parameters (BOD + Total Suspended Solids). Your NPDES permit typically requires 3-5 BOD tests per week under Method 5210B — a workflow that fills a 171L incubator regularly with 30-40 BOD bottles per test round. Our chamber capacity handles a full week's operational BOD load without batching.

Applications

Application Setpoint Typical use
EPA 5210B BOD testing 20°C ± 1°C Municipal wastewater plant NPDES compliance, industrial discharger monitoring
Microbiology — E. coli / coliforms 35-37°C Water quality, food safety, clinical microbiology screening
Microbiology — general bacteria 25-30°C Environmental isolates, soil microbiology, general TC
Pharmaceutical stability 25°C or 30°C or 40°C ICH Q1A(R2) intermediate + accelerated stability studies
Plant tissue culture 22-25°C Micropropagation, callus culture, agricultural biotech
Seed germination testing 15-30°C Agricultural seed labs (AOSA compliance), university programs
Entomology rearing 25-28°C Insect life-cycle studies, pesticide efficacy, biocontrol research
Water quality — nitrification / denitrification 10-30°C Nutrient removal process studies
Cold storage / refrigerated culture 4-10°C Slow bacterial growth, food shelf-life studies

Comparison to alternatives

Feature SciMed BOD Incubator Thermo Precision 815 VWR 2005 SHEL LAB SRI20
Price $14,999 $22,000-$28,000 $18,000-$25,000 $16,000-$22,000
Chamber size 171 L / 6.1 cu.ft. 170 L 170 L 170 L
Temperature range 5-50°C 5-40°C 2-45°C 5-40°C
Stability ±0.5°C ±0.5°C ±0.5°C ±0.5°C
Controller Deluxe Digital PID Digital PID Digital PID Microprocessor PID
Dual door Yes (acrylic inner) Yes Yes Yes
EPA 5210B Yes Yes Yes Yes
Lead time Same-day US ship 8-12 weeks 6-10 weeks 4-8 weeks
Warranty 2yr parts / 5yr compressor 1yr 2yr 1yr

Best for

  • Municipal wastewater treatment plants — NPDES permit-required 5-day BOD compliance testing (small-to-medium plants: 1-10 MGD)
  • Industrial discharge permit monitoring — food & beverage, pulp & paper, chemical plants, dairy, brewery + distillery
  • Environmental testing laboratories — commercial contract labs running BOD + microbiology on client samples
  • State + regional water quality labs — surface water monitoring, EPA + state DEQ analysis
  • Pharmaceutical stability chambers — ICH Q1A(R2) 25°C accelerated + 30°C intermediate conditions
  • Microbiology + clinical labs — 35°C + 37°C bacterial culture
  • University environmental engineering + microbiology programs — teaching + research
  • Seed testing laboratories — AOSA-certified germination testing
  • Agricultural biotech / plant tissue culture — micropropagation facilities
  • Contract research + testing organizations — high-volume multi-client work

Construction — built for years of continuous duty

  • Double-wall construction — insulation between inner + outer walls minimizes heat exchange with lab ambient, reduces compressor duty cycle, extends equipment life
  • Inner chamber: anodized aluminum (economical, corrosion-resistant) or highly polished SS 304 (recommended for microbiology + pharmaceutical stability applications where cleaning aggressively is common)
  • Outer body: thick mild steel with powder-coated matte finish — hospital / lab professional appearance, cleans easily
  • Dual door design: outer double-wall door with magnetic gasket + lock & key + inner transparent acrylic door for observation without breaking temperature during 5-day BOD incubations
  • Shelves: 2 or 3 adjustable perforated SS shelves (specify at order) — perforation allows air circulation around samples for uniform temperature
  • Sealed refrigeration system: high-efficiency compressor with built-in overload protection, thermal safety cut-out, and environmentally-friendly refrigerant (R-134a or R-600a)
  • Integrated heating element: for setpoints above ambient without secondary equipment
  • Forced-air circulation: internal fan drives uniform temperature distribution — critical for the ±1°C EPA requirement across a full BOD bottle rack
  • LED interior lighting: door-switch activated auto on/off; LED is preferred over incandescent because it produces negligible heat that would perturb temperature control

Buying for a wastewater plant, environmental lab, or pharma facility?

SciMed supplies BOD incubators direct to municipal wastewater plants, state / regional environmental laboratories, commercial contract testing labs, pharmaceutical stability chambers, and academic environmental engineering programs.

  • Volume pricing on 3+ unit orders — multi-lab pharma stability build-outs, state DEQ network procurements
  • Net-30 invoicing for verified municipal wastewater plants, state agencies, universities, pharma companies
  • SAM.gov + GSA compliant procurement — federal environmental labs, EPA regional labs
  • Calibration + validation documentation — factory NIST-traceable temperature verification records included; on-site calibration by certified contractors on request
  • IQ/OQ documentation for pharma stability chamber deployments
  • International DDP shipping — India, LATAM, MENA, SE Asia, GCC, UK, EU, AU/NZ
  • Freight quotes on request — chamber ships crated ~180 kg, LTL freight typical for continental US, ocean for 3+ unit international orders
  • Extended service contracts — 5-year all-inclusive service available for critical municipal + pharma installations
  • Equipment financing — via lab equipment lenders (24-60 month terms)
Email procurement →(669) 265-9353

Frequently asked questions

Does this meet EPA Method 5210B requirements?

Yes. EPA 5210B requires 20°C ± 1°C. Our chamber holds ±0.5°C at 20°C setpoint — a 2× safety margin against the compliance target. The Deluxe Digital PID controller provides continuous temperature display; recording your daily setpoint verification (or connecting an external temperature datalogger) satisfies EPA + state NPDES documentation requirements. Independent third-party temperature verification / calibration by a certified provider is standard practice for regulated labs.

How many 300 mL BOD bottles fit at once?

Approximately 40-60 standard 300 mL BOD bottles per full chamber load with 2 shelves. Bottles can be arranged in single or double rows depending on your bottle rack. For high-volume plants running 40-50 samples per week, this capacity supports full weekly workflow without batching.

Can I use this for pharmaceutical stability studies?

Yes. 25°C ± 2°C (intermediate) and 40°C ± 2°C (accelerated) conditions per ICH Q1A(R2) are within range. For 25°C / 60% RH combination testing, this is a temperature-only chamber — humidity control not included. For temperature + humidity stability, contact us for our TH-series stability chambers.

What refrigerant does this use?

R-134a or R-600a (environmentally-friendly, non-CFC, low GWP). Compliant with EPA Section 608 refrigerant regulations for US operation. No ozone-depleting refrigerants used.

How long does it take to reach setpoint?

Cool-down from ambient (25°C) to 20°C setpoint: typically 20-30 minutes to enter the ±1°C compliance band. Cool-down to 5°C: 45-60 minutes. Heat-up from ambient to 37°C: 15-25 minutes. This is comparable to Thermo, VWR, and SHEL LAB units — physics of moving 171L of air through a temperature range.

Does the interior light heat the chamber?

Minimally. The LED interior lighting is door-switch activated (only on when door is open) and LED-based (produces negligible heat vs incandescent). During normal BOD incubation with door closed for 5 days, the light is off — no temperature perturbation.

What ambient conditions does this require?

15-32°C ambient recommended for reliable performance. Cooling to 5°C from a 32°C+ hot lab is possible but reduces compressor life and slows cool-down. For labs without air conditioning in summer, we recommend positioning the incubator away from direct sunlight and away from heat-generating equipment (autoclaves, ovens). Verify at least 200 mm clearance behind the chamber for ventilation.

What voltage do I need?

Specify 110V or 220V at order. US wastewater plants + laboratories typically use 110V (standard 15A circuit). International + industrial installations typically 220V. Universal 100-240V configuration available on request (+$400).

Do you provide IQ/OQ documentation for pharma?

Yes. Installation qualification (IQ) and operational qualification (OQ) protocol templates available on request for pharma stability chamber installations. Third-party validation by a certified contractor recommended for full 21 CFR Part 11 compliance.

What's the warranty?

2-year parts + labor on chamber, doors, PID controller, refrigeration system, heating element. 5-year on compressor (typical service life 15-20 years in continuous BOD duty). Cosmetic damage, damage from operation outside 15-32°C ambient, and modifications not covered. Replacement parts stocked in San Jose warehouse for 8+ years post-purchase.

How is this shipped internationally?

US: LTL freight (crated ~180 kg, lift-gate required). International: ocean freight DDP for orders 2+ units, DHL Express DDP for single-unit urgent. Ships to India, LATAM (Mexico/Brazil/Colombia), MENA (UAE/Saudi/Egypt), SE Asia (Indonesia/Vietnam), Sub-Saharan Africa (Kenya/Nigeria/South Africa), GCC, UK, EU, AU/NZ. Custom duty/taxes handled under DDP where applicable.

Why buy direct from SciMed

  • ~50% of Thermo Precision 815 pricing — same 5-50°C range, ±0.5°C stability, dual door, PID digital controller
  • Same-day US ship — no 8-12 week manufacturer lead time (critical for wastewater plants replacing failed units)
  • 2-year parts + 5-year compressor warranty — exceeds Thermo's 1-year standard
  • NPDES + EPA-ready — factory temperature verification documentation for state DEQ / EPA discharge monitoring reports
  • Municipal + industrial procurement — SAM.gov, GSA, Net-30, PO acceptance, tax-exempt purchasing
  • Pharma-ready — IQ/OQ templates, calibration documentation for stability chamber deployments
  • International DDP — environmental + pharma markets globally
  • Extended service contracts — for critical municipal / pharma applications

Shipping: Continental US LTL freight (lift-gate required, ~180 kg crated). International DDP ocean freight or DHL Express. Municipal / environmental / pharma procurement: clinic@scimedstore.com.

View full details